3 set the insulation batt on the floor with the chalk line facing toward the ceiling.
Spray foam insulation over wiring.
If you don t see a line apply another coat of chalk to the wire and push the insulation back into the cavity.
I believe either too much foam was installed in one lift or the foam rolled over on itself during the installation process causing a build up of heat which melted the wire insulation.
One downside to having spray foam insulation is that it is hard to perform any modifications like adding new electrical wiring and outlets once it is installed.
Regardless a red flag has gone up and the state of minnesota is looking into the issue.
Other options such as spray foam or loose insulation are also a possibility but in all cases the insulation needs to be installed after the wiring is done.
After the wiring is in place the insulation can be laid in.
I guess the inspector was concerned about heat.
So i have never thought about this before.
Wiring in spray foam insulation on a related note the iaei published a report back in sept.
While there may be debate between individual contractors about spraying foam insulation over electrical wires industry guidelines state that spray foam insulation can be applied directly over electrical wiring.
If using great stuff pro with foam dispensing gun follow these additional steps before application.
The results are rather interesting.
This is not for a client i am just trying to get better educated.
Never allow foam to touch exposed wiring.
A safe practice is to avoid working in the area while spraying is taking place and for a period of time up to 24 hours thereafter as recommended by the spray foam manufacturer.
Most homes are insulated using batt or roll insulation.
At the finishing stage.
Spray foam insulation is generally used in most modern houses to provide protection against very hot or very cold conditions by keeping the temperature inside at a tolerable level.
Store or dispose of the product as per directed on label.
I do not see a lot of spray foam in the walls in new construction around here.
Code officials have accepted the use of spray foam insulation in residences for a long time and it s common to encapsulate non metalic cable romex in spray foam.
2003 about the oversite of nm b bundling and bundling in fire draft applications.
The city inspector was giving the electrician a hard time about it but passed it.
Foam should be tack free in 10 to 15 minutes.
1 remove the wiring first and put it in conduit over the sheetrock when i install that over the foam.
Does spray foam insulation affect electrical or other work in the attic.
The insulator spray foamed closed cell all of the roughed in romex.